EA-16-241 · CAL · Issued 2017-04-13 · Reactor Licensees
Action
EA Number
EA-16-241
Licensee
NOV (White)
Category
Reactor Licensees
Action type
CAL
Date issued
2017-04-13
Description
On April 13, 2017, the NRC issued a Notice of Violation to Exelon Nuclear (Exelon) for a violation of Technical Specification 6.8.1, “Procedures and Programs,” at Oyster Creek associated with a White Significance Determination Process finding. Specifically, Exelon failed to properly implement a procedure for rebuilding and reassembly of an electromagnetic relief valve. The maintenance instruction directed reinstallation of a lever plate with previously removed lock washers. By failing to reinstall the lock washers, the licensee caused excessive friction between the solenoid frame and the cut-out switch lever plate, causing the cut-out switch lever to become bound in the energized position and rendering the valve unable to perform its safety-related function. Additionally, this incorrect reassembly resulted in the relief valve being inoperable for greater than the Technical Specification allowed outage time for the Automatic Depressurization System.